Water source heat pumps

Filter
Country  
Category  
Technology  
Manufacturer  
  1. Dimplex 2 items
  2. Hoval 2 items
  3. Midea 4 items
  4. Stiebel Eltron 7 items
  5. Walter Bösch GmbH & Co KG 1 item
  6. Waterkotte 3 items
  7. Wieder 1 item
show more show less
Energy source  
EU energy label  
Seasonal COP  
Cooling capacity  
Coefficient of performance (COP)  
Heating capacity  
Page
Set Descending Direction
  1. WPL 13 cool

    Air | Water heat pump with small footprint due to compact design for optional indoor or outdoor installation with cooling function. The metal housing is hot-dip galvanized and white in the color, stove enamelled. For monoenergetic heating and high hot water temperatures, the emergency / booster heater is fitted as standard. Defrosting of the evaporator by circulation reversal. The electronic expansion valve optimizes the coefficient of performance across the entire range of application. The heat pump is filled with the safety refrigerant R407 C. The heat pump is controlled via a BUS line.
    Add to List
    Energy source
    Electricity
    Heating capacity
    8.10 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A+
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.40 COP
  2. WPL 57 Set A

    APPLICATION: Air | Water heat pump for outdoor installation. Suitable for multi-family houses and commercial applications due to up to 24 kW as single unit and up to 144 kW in cascade. The housing design allows a flexible installation - even in free field. EQUIPMENT / COMFORT: Optimized sound reduction through encapsulated refrigeration circuit and decoupled compressors. The large finned distance of the evaporator allows for low air resistance and, in conjunction with the modulating fan for a low sound power level. The heat pump controller (accessory) in conjunction with the ISG (optional accessory) enables control of the system in the home network or with a mobile device. With integrated heat quantity and electricity metering via cooling circuit data. Via a 230 V signal, fault messages can be processed externally. If required, the integration into a building automation can be realized via a software extension. The refrigeration circuit is hermetically sealed, factory-tested for leaks and filled with R407C safety refrigerant. EFFICIENCY: Demand-dependent and energy-efficient circulation reverse dew. The condensate tray is heated by the refrigeration circuit to allow efficient defrosting. INSTALLATION: The metal housing is protected against corrosion, made of galvanized and powder-coated sheet steel and stove-enamelled in the color alpine white.
    Add to List
    Energy source
    Electricity
    Heating capacity
    9.03 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A+
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.30 COP
  3. SW 90

    SW 90
    Add to List
    Energy source
    Electricity
    Heating capacity
    11.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    3.80 COP
  4. WI 14TU

    WI 14TU
    Add to List
    Energy source
    Electricity
    Heating capacity
    13.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    3.80 COP
  5. WPL 16 S Trend Set 5

    Inverter air | Water heat pump for compact outdoor installation for heating and cooling. Heat pump basic unit made of EPP for weight reduction and easy transport. The cladding made of metal in a separate packaging unit for easy installation on the base unit. The large finned distance of the evaporator allows low air resistance and in combination with the modulating fan in the outdoor unit, it ensures a low sound power level. The inverter compressor is regulated as required and ensures high efficiency. The 4-2-way valve enables the circulation reversal defrosting as well as the changeover from heating to cooling operation. The refrigeration circuit is filled with the safety refrigerant R410A. Including all safety devices. For operation, an external emergency / auxiliary heater as well as the heat pump manager WPM are required for control. In combination with the hydraulic module or memory modules, these functions are covered. The set includes: Heat pump of the Trend series, Integral storage HSBC 200 and vibration isolation for connection to the heat pump.
    Add to List
    Energy source
    Electricity
    Heating capacity
    5.05 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    5.04 COP
  6. LRSJ-140/NYN1-A1

    Water heat pumps for swimming pools
    Add to List
    Energy source
    Electricity
    Heating capacity
    13.60 kW
    Cooling capacity
    10.35 kW
    EU energy label
    A
    Seasonal COP
    12.17
    Coefficient of performance (COP)
    5.33 COP
  7. LRSJ-80/NYN1-A1

    Water heat pump for swimming pools
    Add to List
    Energy source
    Electricity
    Heating capacity
    8.00 kW
    Cooling capacity
    5.80 kW
    EU energy label
    A
    Seasonal COP
    13.19
    Coefficient of performance (COP)
    5.27 COP
  8. DS5017.5 Ai A

    DS5017.5 Ai A
    Add to List
    Energy source
    Electricity
    Heating capacity
    16.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A+++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    3.80 COP
  9. WPL 18 E

    Air | Water heat pump with steam intermediate injection for heating. Can be used as outdoor or indoor installation variant with corresponding accessories. The cladding consists of a robust metal housing made of hot-dip galvanized, powder-coated and stove-enamelled steel. The refrigeration circuit is hermetically sealed, factory tested for leaks and filled with the R407C safety refrigerant. Double vibration decoupling of the compressor to reduce the sound power level. The intercooler injectors cool the scroll compressor at low outdoor temperatures and achieve higher heat output. The large finned spacing of the evaporator allows for lower air resistance for sound reduction and better defrosting. The 4-2 way valve allows the circulation reversal. Biflow-capable electronic expansion valve with its own control and control via the internal heat pump control (IWS) to optimize the overheating control and thus to improve the COP. Time-optimized and energy-efficient circulation reversal protection. Heating the condensate pan through the refrigeration circuit for efficient defrosting. With integrated heat quantity and electricity metering via cooling circuit data. Including all safety devices. Heat pump manager WPM 3 (accessory) necessary for control.
    Add to List
    Energy source
    Electricity
    Heating capacity
    11.30 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.60 COP
Page