Heat pumps

Filter
  1. EU energy label A++ Remove this item
Clear all
Country  
Category  
Technology  
Manufacturer  
  1. Buderus 3 items
  2. Cooper&Hunter 12 items
  3. Dimplex 18 items
  4. Hoval 2 items
  5. Junkers Bosch 3 items
  6. KNV 8 items
  7. Ochsner 2 items
  8. Solarfocus 1 item
  9. Stiebel Eltron 5 items
  10. Vaillant 2 items
  11. Walter Bösch GmbH & Co KG 3 items
  12. Weider 1 item
  13. Wieder 1 item
show more show less
Energy source  
EU energy label  
Seasonal COP  
Cooling capacity  
Coefficient of performance (COP)  
Heating capacity  
Page
Set Descending Direction
  1. CH-S24FTXE

    Heat-pump Alpha series
    Add to List
    Energy source
    Electricity
    Heating capacity
    7.25 kW
    Cooling capacity
    6.70 kW
    EU energy label
    A++
    Seasonal COP
    4.60
    Coefficient of performance (COP)
    3.73 COP
  2. GMLW 14 plus

    GMLW 14 plus
    Add to List
    Energy source
    Electricity
    Heating capacity
    13.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    4.10 COP
  3. flexoTHERM

    flexoTHERM
    Add to List
    Energy source
    Electricity
    Heating capacity
    20.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    5.00 COP
  4. SIK 8TES

    SIK 8TES
    Add to List
    Energy source
    Electricity
    Heating capacity
    8.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    5.00 COP
  5. SI 14TU

    SI 14TU
    Add to List
    Energy source
    Electricity
    Heating capacity
    14.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    5.00 COP
  6. LA 25TU

    Outdoor heat pump with wall-mounted heat pump manager WPM EconPlus and two compressors for power reduction in partial load operation. Sound-optimized by slow-running owl-wing fan with naturally quiet air noise, enclosed compressor chamber and freely oscillating compressor base plate for structure-borne sound decoupling. High performance figures due to high performance evaporator and fulfillment of the requirements according to EN 14511 for larger volume flows on the heat utilization side. High operational safety through sensory monitoring of the refrigeration circuit with demand-dependent defrosting; Integrated heat quantity counting (display of the calculated heat quantity for heating and hot water preparation at the heat pump manager WPM EconPlus). Access for service work on the outlet side, when installing close to the wall, the minimum distances must be observed. Easy transport by means of lift trucks (wheelchair accessible) or lifting lugs. Universal design with two compressors for modulating operation, optional hot water preparation and flexible expansion options for: bivalent or bivalent regenerative operation Distribution systems with unmixed and mixed heating circuits Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included. Electrical connecting cable EVL ..U between heat pump and heat pump manager must be ordered separately.
    Add to List
    Energy source
    Electricity
    Heating capacity
    19.60 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.90 COP
  7. LI 16TES

    Heating heat pump for indoor installation with integrated control WPM 2007 plus. The control unit integrated in a brown-red design panel can also be used as a wired remote control by means of a wall mounting set (special accessory MS PGD). The integrated air duct allows the corner or wall installation with air ducts on the intake and exhaust side. Sound-optimized by low-noise axial fan and vibration-decoupled compressor. High performance figures due to an evaporator optimized for heating operation and energy-efficient defrost by circulation reversal. Universal design with optional DHW heating and flexible expansion options for: bivalent or bivalent regenerative mode Distribution systems with unmixed and mixed heating circuits Built-in pipe heater (2/4/6 kW) With an outside temperature of -10 ° C, a maximum flow temperature of 53 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    13.40 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.30 COP
  8. SI 8TU

    SI 8TU
    Add to List
    Energy source
    Electricity
    Heating capacity
    8.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    5.00 COP
  9. LA 6S-TU

    Outdoor heating heat pump with wall-mounted heat pump manager WPM Econ5Plus. Sound-optimized by slow-running owl-wing fan with naturally quiet air noise, enclosed compressor chamber and freely oscillating compressor base plate for structure-borne sound decoupling. High performance figures due to high-performance evaporator, electronic expansion valve and fulfillment of the requirements according to EN 14511 for larger volume flows on the heat utilization side. High operational safety through sensory monitoring of the refrigeration circuit with demand-dependent defrosting; integrated heat quantity counting (display of the calculated heat quantity for heating and hot water preparation at the heat pump manager). The small minimum wall clearance on the suction side of 50 cm allows installation close to the wall. Universal design for low-temperature heating systems with flexible expansion options for: bivalent or bivalent regenerative operation Distribution systems with unmixed and mixed heating circuits Use of variable-load tariffs (SG Ready) With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Flow and return sensor integrated; Outdoor sensor (standard NTC-2) included. Dirt catcher and flow switch integrated. The electrical connection between the control to be mounted in the building and the outdoor unit is made using a shielded 2-core data cable (for example, LiYY 2x0.6 mm² or J-Y (ST) Y..LG2x0.28mm2), which is not included in the delivery.ed and mixed heating circuits With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    7.20 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    4.70 COP
Page
Set Descending Direction