Heat pumps

Filter
  1. Country Turkey Remove this item
Clear all
Country  
Category  
Technology  
Manufacturer  
  1. Buderus 3 items
  2. CLIVET 16 items
  3. Cooper&Hunter 21 items
  4. Dimplex 16 items
  5. Hoval 2 items
  6. Junkers Bosch 3 items
  7. KNV 8 items
  8. Midea 15 items
  9. Ochsner 3 items
  10. Solarfocus 1 item
  11. Stiebel Eltron 3 items
  12. Vaillant 2 items
  13. Walter Bösch GmbH & Co KG 3 items
  14. Waterkotte 3 items
  15. Weider 1 item
  16. Wieder 1 item
show more show less
Energy source  
EU energy label  
Seasonal COP  
Cooling capacity  
Coefficient of performance (COP)  
Heating capacity  
Page
Set Descending Direction
  1. CH-S18FTXE

    Heat-pump Alpha series
    Add to List
    Energy source
    Electricity
    Heating capacity
    5.30 kW
    Cooling capacity
    5.00 kW
    EU energy label
    A++
    Seasonal COP
    4.60
    Coefficient of performance (COP)
    3.84 COP
  2. CPAN-XHE2E - 130

    Recycled air heat pump
    Add to List
    Energy source
    Electricity
    Heating capacity
    98.10 kW
    Cooling capacity
    90.30 kW
    EU energy label
    A
    Seasonal COP
    13.00
    Coefficient of performance (COP)
    5.74 COP
  3. OCHSNER AIR 717 C EAGLE

    OCHSNER AIR 717 C EAGLE
    Add to List
    Energy source
    Electricity
    Heating capacity
    17.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    4.10 COP
  4. CSRN-XHE2-FFA - 24.4

    Air cooled reversible heat pump
    Add to List
    Energy source
    Electricity
    Heating capacity
    89.50 kW
    Cooling capacity
    90.40 kW
    EU energy label
    A
    Seasonal COP
    13.23
    Coefficient of performance (COP)
    4.32 COP
  5. CH-S12FTXS-M

    Heat-pump Arctic Design series
    Add to List
    Energy source
    Electricity
    Heating capacity
    3.97 kW
    Cooling capacity
    3.53 kW
    EU energy label
    A++
    Seasonal COP
    4.90
    Coefficient of performance (COP)
    4.71 COP
  6. LI 12TU

    Heating heat pump for indoor installation with integrated control WPM EconPlus. Sound-optimized by low-speed EC-3D radial fan, enclosed compressor chamber and freely oscillating compressor base plate for structure-borne sound decoupling. High performance figures due to high-performance evaporator, electronic expansion valve and fulfillment of the requirements according to EN 14511 for larger volume flows on the heat utilization side. High operational safety through sensory monitoring of the refrigeration circuit with demand-dependent defrosting; Integrated heat quantity counting (display of the calculated heat quantity for heating and hot water preparation at the heat pump manager WPM EconPlus). The integrated air duct with 90 ° deflection allows a direct corner installation without air ducts or a wall installation with air ducts on the outlet side. Variable installation by air intake from the rear, flexible air outlet to the right, left or top and the possibility to move the hydraulic connections from right to left. The control unit integrated in a brown-red design panel can also be used as a wired remote control by means of a wall mounting set (special accessory MS PGD). Universal design for low-temperature heating systems with flexible expansion options for: Room temperature control via Smart-RTC (optional) bivalent or bivalent regenerative mode Distribution systems with unmixed and mixed heating circuits With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    9.40 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    4.00 COP
  7. WPL 08 S Trend Set 2

    Inverter air | Water heat pump for compact outdoor installation for heating and cooling. Heat pump basic unit made of EPP for weight reduction and easy transport. The cladding made of metal in a separate packaging unit for easy installation on the base unit. The large finned distance of the evaporator allows low air resistance and in combination with the modulating fan in the outdoor unit, it ensures a low sound power level. The inverter compressor is regulated as required and ensures high efficiency. The 4-2-way valve enables the circulation reversal defrosting as well as the changeover from heating to cooling operation. The refrigeration circuit is filled with the safety refrigerant R410A. Including all safety devices. For operation, an external emergency / auxiliary heater as well as the heat pump manager WPM are required for control. In combination with the hydraulic module or memory modules, these functions are covered. The set includes: Heat pump of the Trend series, hydraulic module HM Trend incl. Connection set AS-HM Trend, vibration isolation for connection to the heat pump, hot water storage tank SBB 300 WP Trend for WPL 08/12 Trend or hot water storage tank SBB 400 WP Trend for WPL 16/22/28 trend.
    Add to List
    Energy source
    Electricity
    Heating capacity
    2.79 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.89 COP
  8. SI 8TU

    SI 8TU
    Add to List
    Energy source
    Electricity
    Heating capacity
    8.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    5.00 COP
  9. LA 6S-TU

    Outdoor heating heat pump with wall-mounted heat pump manager WPM Econ5Plus. Sound-optimized by slow-running owl-wing fan with naturally quiet air noise, enclosed compressor chamber and freely oscillating compressor base plate for structure-borne sound decoupling. High performance figures due to high-performance evaporator, electronic expansion valve and fulfillment of the requirements according to EN 14511 for larger volume flows on the heat utilization side. High operational safety through sensory monitoring of the refrigeration circuit with demand-dependent defrosting; integrated heat quantity counting (display of the calculated heat quantity for heating and hot water preparation at the heat pump manager). The small minimum wall clearance on the suction side of 50 cm allows installation close to the wall. Universal design for low-temperature heating systems with flexible expansion options for: bivalent or bivalent regenerative operation Distribution systems with unmixed and mixed heating circuits Use of variable-load tariffs (SG Ready) With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Flow and return sensor integrated; Outdoor sensor (standard NTC-2) included. Dirt catcher and flow switch integrated. The electrical connection between the control to be mounted in the building and the outdoor unit is made using a shielded 2-core data cable (for example, LiYY 2x0.6 mm² or J-Y (ST) Y..LG2x0.28mm2), which is not included in the delivery.ed and mixed heating circuits With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    7.20 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    4.70 COP
Page
Set Descending Direction