Heat pumps

Filter
  1. Country Azerbaijan Remove this item
  2. Manufacturer Walter Bösch GmbH & Co KG Remove this item
  3. Manufacturer Dimplex Remove this item
Clear all
Country  
Category  
Technology  
Manufacturer  
  1. AHI Carrier 6 items
  2. Bosch 10 items
  3. Buderus 3 items
  4. CLIVET 16 items
  5. Cooper&Hunter 22 items
  6. Daikin 3 items
  7. Danfoss 6 items
  8. Dimplex 59 items
  9. HiRef Spa 305 items
  10. Hoval 30 items
  11. JUNKERS 16 items
  12. Junkers Bosch 3 items
  13. KNV 8 items
  14. LG 15 items
  15. Midea 15 items
  16. Mitsubishi 3 items
  17. Mitsubishi Electric 1 item
  18. Walter Bösch GmbH & Co KG 3 items
show more show less
Energy source  
EU energy label  
Seasonal COP  
Cooling capacity  
Coefficient of performance (COP)  
Heating capacity  
Page
Set Descending Direction
  1. SIK9TE

    Operating temperature limit (saline solution) from –5 ° C to +25 ° C; Monoethylene glycol antifreeze; Temperature of the supply / return coolant circuit, ˚С / ˚С to 58 / from 18; Noise level dB (A) 51; Dimensions (width x depth x height) ** mm 652x 688 x 1115; Weight (including packaging) kg 180; Rated voltage / current protection V / A 400/16; Frost Protection: Yes.
    Add to List
    Energy source
    Electricity
    Heating capacity
    9.20 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A
    Seasonal COP
    3.25
    Coefficient of performance (COP)
    4.40 COP
  2. SI14TE

    Operating temperature limit (saline solution) from –5 ° C to +25 ° C; Monoethylene glycol antifreeze; Temperature of the supply / return coolant circuit, ˚С / ˚С to 58 / from 18; Noise level dB (A) 56; Dimensions (width x depth x height) ** mm 650x 462 x 805; Weight (including packaging) kg 130; Rated voltage / current protection V / A 400/16; Frost Protection: Yes.
    Add to List
    Energy source
    Electricity
    Heating capacity
    14.50 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A
    Seasonal COP
    3.50
    Coefficient of performance (COP)
    4.50 COP
  3. SIK16ME

    Operating temperature limit (saline solution) from –5 ° C to +25 ° C; Monoethylene glycol antifreeze; Temperature of the supply / return coolant circuit, ˚С / ˚С to 58 / from 18; Noise level dB (A) 51; Dimensions (width x depth x height) ** mm 652x 688 x 1115; Weight (including packaging) kg 203; Rated voltage / current protection V / A 230/25; Frost Protection: Yes.
    Add to List
    Energy source
    Electricity
    Heating capacity
    15.80 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A
    Seasonal COP
    3.07
    Coefficient of performance (COP)
    4.20 COP
  4. SIH6TE

    Operating temperature limit (saline solution) from –5 ° C to +25 ° C; Monoethylene glycol antifreeze; Temperature of the supply / return coolant circuit, ˚С / ˚С to 70 / from 18; Noise level dB (A) 54; Dimensions (width x depth x height) ** mm 805x 462 x 650; Weight (including packaging) kg 118; Rated voltage / current protection V / A 400/16; Frost Protection: Yes.
    Add to List
    Energy source
    Electricity
    Heating capacity
    6.40 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A
    Seasonal COP
    4.00
    Coefficient of performance (COP)
    4.70 COP
  5. LA 6S-TU

    Outdoor heating heat pump with wall-mounted heat pump manager WPM Econ5Plus. Sound-optimized by slow-running owl-wing fan with naturally quiet air noise, enclosed compressor chamber and freely oscillating compressor base plate for structure-borne sound decoupling. High performance figures due to high-performance evaporator, electronic expansion valve and fulfillment of the requirements according to EN 14511 for larger volume flows on the heat utilization side. High operational safety through sensory monitoring of the refrigeration circuit with demand-dependent defrosting; integrated heat quantity counting (display of the calculated heat quantity for heating and hot water preparation at the heat pump manager). The small minimum wall clearance on the suction side of 50 cm allows installation close to the wall. Universal design for low-temperature heating systems with flexible expansion options for: bivalent or bivalent regenerative operation Distribution systems with unmixed and mixed heating circuits Use of variable-load tariffs (SG Ready) With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Flow and return sensor integrated; Outdoor sensor (standard NTC-2) included. Dirt catcher and flow switch integrated. The electrical connection between the control to be mounted in the building and the outdoor unit is made using a shielded 2-core data cable (for example, LiYY 2x0.6 mm² or J-Y (ST) Y..LG2x0.28mm2), which is not included in the delivery.ed and mixed heating circuits With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    7.20 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    4.70 COP
  6. SIKH9TE

    Operating temperature limit (saline solution) from –5 ° C to +25 ° C; Monoethylene glycol antifreeze; Temperature of the supply / return coolant circuit, ˚С / ˚С to 70 / from 18; Noise level dB (A) 49; Dimensions (width x depth x height) ** mm 652x 688 x 1115; Weight (including packaging) kg 230; Rated voltage / current protection V / A 400/16; Frost Protection: Yes.
    Add to List
    Energy source
    Electricity
    Heating capacity
    9.40 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A
    Seasonal COP
    3.50
    Coefficient of performance (COP)
    4.70 COP
  7. LI 9TU

    Heating heat pump for indoor installation with integrated control WPM EconPlus. Sound-optimized by low-speed EC-3D radial fan, enclosed compressor chamber and freely oscillating compressor base plate for structure-borne sound decoupling. High performance figures due to high-performance evaporator, electronic expansion valve and fulfillment of the requirements according to EN 14511 for larger volume flows on the heat utilization side. High operational safety through sensory monitoring of the refrigeration circuit with demand-dependent defrosting; Integrated heat quantity counting (display of the calculated heat quantity for heating and hot water preparation at the heat pump manager WPM EconPlus). The integrated air duct with 90 ° deflection allows a direct corner installation without air ducts or a wall installation with air ducts on the outlet side. Variable installation by air intake from the rear, flexible air outlet to the right, left or top and the possibility to move the hydraulic connections from right to left. The control unit integrated in a brown-red design panel can also be used as a wired remote control by means of a wall mounting set (special accessory MS PGD). Universal design for low-temperature heating systems with flexible expansion options for: Room temperature control via Smart-RTC (optional) bivalent or bivalent regenerative mode Distribution systems with unmixed and mixed heating circuits With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    6.80 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.90 COP
  8. SI24TE

    Operating temperature limit (saline solution) from –5 ° C to +25 ° C from - + 5 ° C to + 30C; Monoethylene glycol antifreeze; Temperature of the supply / return coolant circuit, ˚С / ˚С to 55 ±1; Noise level dB (A) 62; Dimensions (width x depth x height) ** mm 1000x 775x 1660; Weight (including packaging) kg 385; Rated voltage / current protection V / A 400/20; Frost Protection: Yes.
    Add to List
    Energy source
    Electricity
    Heating capacity
    24.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A
    Seasonal COP
    3.15
    Coefficient of performance (COP)
    4.30 COP
  9. SI16TR

    Operating temperature limit (saline solution) from –5 ° C to +25 ° C from - + 5 ° C to + 25C; Monoethylene glycol antifreeze; Temperature of the supply / return coolant circuit, ˚С / ˚С to 58 / from 18; Noise level dB (A) 56; Dimensions (width x depth x height) ** mm 640x 624 x 1220; Weight (including packaging) kg 160; Rated voltage / current protection V / A 400/16; Frost Protection: Yes.
    Add to List
    Energy source
    Electricity
    Heating capacity
    16.40 kW
    Cooling capacity
    21.50 kW
    EU energy label
    A
    Seasonal COP
    3.98
    Coefficient of performance (COP)
    4.00 COP
Page
Set Descending Direction