Heat pumps

Filter
  1. Country Macedonia Remove this item
Clear all
Country  
Category  
Technology  
Manufacturer  
  1. Buderus 3 items
  2. CLIVET 16 items
  3. Cooper&Hunter 21 items
  4. Dimplex 16 items
  5. Hoval 2 items
  6. Junkers Bosch 3 items
  7. KNV 8 items
  8. Midea 15 items
  9. Ochsner 3 items
  10. Solarfocus 1 item
  11. Stiebel Eltron 3 items
  12. Vaillant 2 items
  13. Walter Bösch GmbH & Co KG 3 items
  14. Waterkotte 3 items
  15. Weider 1 item
  16. Wieder 1 item
show more show less
Energy source  
EU energy label  
Seasonal COP  
Cooling capacity  
Coefficient of performance (COP)  
Heating capacity  
Page
Set Descending Direction
  1. flexoTHERM

    flexoTHERM
    Add to List
    Energy source
    Electricity
    Heating capacity
    20.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    5.00 COP
  2. Thermalia

    Thermalia
    Add to List
    Energy source
    Electricity
    Heating capacity
    12.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    3.80 COP
  3. CH-S09FTXLA

    Heat-pump Arctic Inverter series
    Add to List
    Energy source
    Electricity
    Heating capacity
    2.80 kW
    Cooling capacity
    2.60 kW
    EU energy label
    A++
    Seasonal COP
    5.10
    Coefficient of performance (COP)
    4.59 COP
  4. CH-S09FTXTB2S-W

    Heat-pump ICY series
    Add to List
    Energy source
    Electricity
    Heating capacity
    3.00 kW
    Cooling capacity
    2.60 kW
    EU energy label
    A+++
    Seasonal COP
    5.10
    Coefficient of performance (COP)
    4.62 COP
  5. Energy source
    Electricity
    Heating capacity
    14.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    5.00 COP
  6. LI 9TU

    Heating heat pump for indoor installation with integrated control WPM EconPlus. Sound-optimized by low-speed EC-3D radial fan, enclosed compressor chamber and freely oscillating compressor base plate for structure-borne sound decoupling. High performance figures due to high-performance evaporator, electronic expansion valve and fulfillment of the requirements according to EN 14511 for larger volume flows on the heat utilization side. High operational safety through sensory monitoring of the refrigeration circuit with demand-dependent defrosting; Integrated heat quantity counting (display of the calculated heat quantity for heating and hot water preparation at the heat pump manager WPM EconPlus). The integrated air duct with 90 ° deflection allows a direct corner installation without air ducts or a wall installation with air ducts on the outlet side. Variable installation by air intake from the rear, flexible air outlet to the right, left or top and the possibility to move the hydraulic connections from right to left. The control unit integrated in a brown-red design panel can also be used as a wired remote control by means of a wall mounting set (special accessory MS PGD). Universal design for low-temperature heating systems with flexible expansion options for: Room temperature control via Smart-RTC (optional) bivalent or bivalent regenerative mode Distribution systems with unmixed and mixed heating circuits With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    6.80 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.90 COP
  7. TopLine 1255-12

    TopLine 1255-12
    Add to List
    Energy source
    Electricity
    Heating capacity
    12.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    5.00 COP
  8. CS7000iAW 7 IR

    CS7000iAW 7 IR
    Add to List
    Energy source
    Electricity
    Heating capacity
    5.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    3.00
    Coefficient of performance (COP)
    4.10 COP
  9. WPL 18 E

    Air | Water heat pump with steam intermediate injection for heating. Can be used as outdoor or indoor installation variant with corresponding accessories. The cladding consists of a robust metal housing made of hot-dip galvanized, powder-coated and stove-enamelled steel. The refrigeration circuit is hermetically sealed, factory tested for leaks and filled with the R407C safety refrigerant. Double vibration decoupling of the compressor to reduce the sound power level. The intercooler injectors cool the scroll compressor at low outdoor temperatures and achieve higher heat output. The large finned spacing of the evaporator allows for lower air resistance for sound reduction and better defrosting. The 4-2 way valve allows the circulation reversal. Biflow-capable electronic expansion valve with its own control and control via the internal heat pump control (IWS) to optimize the overheating control and thus to improve the COP. Time-optimized and energy-efficient circulation reversal protection. Heating the condensate pan through the refrigeration circuit for efficient defrosting. With integrated heat quantity and electricity metering via cooling circuit data. Including all safety devices. Heat pump manager WPM 3 (accessory) necessary for control.
    Add to List
    Energy source
    Electricity
    Heating capacity
    11.30 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Seasonal COP
    5.00
    Coefficient of performance (COP)
    3.60 COP
Page