Cooling

Filter
  1. Country Turkey Remove this item
Clear all
Country  
Category  
Technology  
Manufacturer  
  1. Aermec 24 items
  2. NED 10 items
  3. VEZA 9 items
show more show less
Refrigerant  
Energy label (energy efficiency class)  
Cooling capacity  
Coefficient of performance (COP)  
Rated power  
Page
Set Descending Direction
  1. ANL 20

    Air/water chiller for outdoor installation. Suitable for summer air-conditioning and the production of hot water for small/medium services in residential and commercial buildings • Cooling capacity: 5.7 ÷ 43 kW • R410A refrigerant • Cooling only • Scroll compressor • Axial fan • Plate exchanger • Heat recovery (Option) • Pump kit (Option) • Water tank (Option) • Network operation (Option) • Compatible with ModBus protocol (Option) • Compatible with VMF system (Variable Multi Flow) (Option) • For two pipes plants
    Add to List
    Cooling capacity
    5.66 kW
    Rated power
    1.88 kW
    Refrigerant
    R-410a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    3.01 COP
  2. ANL 202

    Air/water chiller for outdoor installation. Suitable for summer air-conditioning and the production of hot water for small/medium services in residential and commercial buildings • Cooling capacity: 5.7 ÷ 43 kW • R410A refrigerant • Cooling only • Scroll compressor • Axial fan • Plate exchanger • Heat recovery (Option) • Pump kit (Option) • Water tank (Option) • Network operation (Option) • Compatible with ModBus protocol (Option) • Compatible with VMF system (Variable Multi Flow) (Option) • For two pipes plants
    Add to List
    Cooling capacity
    42.60 kW
    Rated power
    13.53 kW
    Refrigerant
    R-410a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    3.15 COP
  3. GWA/EP 412 VV/IY

    Multifunctional four-pipe chiller from the ENERGYPOWER series.
    Add to List
    Cooling capacity
    312.00 kW
    Rated power
    100.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    3.52 COP
  4. NXW 600

    Water-water chiller for indoor installation. Suitable for medium-sized services in residential and commercial buildings. With the addition of a desuperheater or total recovery system, domestic hot water can also be produced. • Cooling capacity: 111 ÷ 510 kW • R410A refrigerant • Cooling only • Scroll compressor • Plate exchanger • Heat recovery (Option) • Pump kit (Option) • Lownoise version (Option) • Network operation (Option) • Compatible with ModBus protocol (Option) • Internet connection (Option) • For two pipes plants
    Add to List
    Cooling capacity
    148.40 kW
    Rated power
    30.70 kW
    Refrigerant
    R-410a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    4.84 COP
  5. ANL70

    Air/water chiller for outdoor installation. Suitable for summer air-conditioning and the production of hot water for small/medium services in residential and commercial buildings • Cooling capacity: 5.7 ÷ 43 kW • R410A refrigerant • Cooling only • Scroll compressor • Axial fan • Plate exchanger • Heat recovery (Option) • Pump kit (Option) • Water tank (Option) • Network operation (Option) • Compatible with ModBus protocol (Option) • Compatible with VMF system (Variable Multi Flow) (Option) • For two pipes plants
    Add to List
    Cooling capacity
    16.39 kW
    Rated power
    4.98 kW
    Refrigerant
    R-410a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    3.29 COP
  6. ANL 30

    Air/water chiller for outdoor installation. Suitable for summer air-conditioning and the production of hot water for small/medium services in residential and commercial buildings • Cooling capacity: 5.7 ÷ 43 kW • R410A refrigerant • Cooling only • Scroll compressor • Axial fan • Plate exchanger • Heat recovery (Option) • Pump kit (Option) • Water tank (Option) • Network operation (Option) • Compatible with ModBus protocol (Option) • Compatible with VMF system (Variable Multi Flow) (Option) • For two pipes plants
    Add to List
    Cooling capacity
    7.44 kW
    Rated power
    2.52 kW
    Refrigerant
    R-410a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    2.95 COP
  7. NXW 1500

    Water-water chiller for indoor installation. Suitable for medium-sized services in residential and commercial buildings. With the addition of a desuperheater or total recovery system, domestic hot water can also be produced. • Cooling capacity: 111 ÷ 510 kW • R410A refrigerant • Cooling only • Scroll compressor • Plate exchanger • Heat recovery (Option) • Pump kit (Option) • Lownoise version (Option) • Network operation (Option) • Compatible with ModBus protocol (Option) • Internet connection (Option) • For two pipes plants
    Add to List
    Cooling capacity
    453.00 kW
    Rated power
    92.60 kW
    Refrigerant
    R-410a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    4.89 COP
  8. GWA/EP 742 VV/IY

    Multifunctional four-pipe chiller from the ENERGYPOWER series.
    Add to List
    Cooling capacity
    564.00 kW
    Rated power
    177.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    3.60 COP
  9. ANL 25

    Air/water chiller for outdoor installation. Suitable for summer air-conditioning and the production of hot water for small/medium services in residential and commercial buildings • Cooling capacity: 5.7 ÷ 43 kW • R410A refrigerant • Cooling only • Scroll compressor • Axial fan • Plate exchanger • Heat recovery (Option) • Pump kit (Option) • Water tank (Option) • Network operation (Option) • Compatible with ModBus protocol (Option) • Compatible with VMF system (Variable Multi Flow) (Option) • For two pipes plants
    Add to List
    Cooling capacity
    6.15 kW
    Rated power
    2.05 kW
    Refrigerant
    R-410a
    Energy label (energy efficiency class)
    A
    Coefficient of performance (COP)
    3.00 COP
Page